| Parameter | Value |
|---|---|
| Orderable part number | EXL1V0707-4R7-R |
| OCL | 4.7 uH ±20% |
| FLL minimum (at Isat) | 2.63 uH |
| Irms typical, +20 °C rise | 10.5 A |
| Irms typical, +40 °C rise | 13.6 A |
| Isat (30% rolloff @ +25 °C) | 14 A |
| DCR typical @ +25 °C | 12.2 mOhm |
| DCR maximum @ +25 °C | 13.5 mOhm |
| SRF typical | 19 MHz |
| Rated operating voltage (across inductor) | 40 V typical |
| Package | 8.7 x 8.3 mm footprint, 7.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
The alloy powder core is the design choice that defines this family: soft saturation means the converter keeps some inductance even at peak transient current, so the control loop never sees the inductor vanish under it. Combined with the low DCR of the moulded winding, it is the standard answer for VRM and point-of-load rails.
DCR 12.2 mOhm is the conduction loss: at rated current it dissipates 1.35 W, and that heat has to leave through the terminals and the board.
Isat is the peak current for approximately 30% rolloff at +25 °C. Because the rolloff is gradual, the useful design question is not "what happens at Isat" but "how much inductance do I still have at my transient peak" - and the soft curve answers that with a usable number.
The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.
EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.
Why does the SRF matter so much here?
These parts reach tens of MHz of self-resonance - far above the converter switching frequency - so the inductor behaves as an inductor across the whole operating band.
What is the rated operating voltage?
The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.
What is the rated operating voltage?
The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.
Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd