| Parameter | Value |
|---|---|
| Orderable part number | EXL1V1010-8R2-R |
| OCL | 8.2 uH ±20% |
| FLL minimum (at Isat) | 4.6 uH |
| Irms typical, +20 °C rise | 12.9 A |
| Irms typical, +40 °C rise | 17.1 A |
| Isat (30% rolloff @ +25 °C) | 16.3 A |
| DCR typical @ +25 °C | 10.8 mOhm |
| DCR maximum @ +25 °C | 12.4 mOhm |
| SRF typical | 11 MHz |
| Rated operating voltage (across inductor) | 40 V typical |
| Package | 12.2 x 11.3 mm footprint, 10 mm height, 3.3-15 uH, 9.9-25 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Moulded construction, magnetically shielded, alloy powder core: this part packs high current into a small footprint with low DCR. The moulding makes the body rugged and the shielding keeps the switching harmonics off the rest of the board.
Copper loss is the efficiency floor. 10.8 mOhm at 25 °C rises about 30% by 100 °C, so the hot-corner budget should use the maximum column, not the typical.
Saturation on a powder core is a curve, not a cliff: Isat is the peak current for approximately 30% rolloff at +25 °C, and beyond it the inductance continues to fall smoothly. Budget the transient peak against the inductance you actually need, not against the part surviving.
The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.
EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.
What is the rated operating voltage?
The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.
Is the part shielded?
Yes, magnetically shielded and moulded, which is what keeps it usable next to sensitive circuitry on a dense VRM board.
What is the rated operating voltage?
The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.
Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd