| Parameter | Value |
|---|---|
| Orderable part number | EXLA1V0402-2R2-R |
| OCL | 2.2 uH ±20% |
| Irms | 8 A |
| Isat (30% rolloff @ +25 °C) | 4.8 A |
| DCR typical @ +25 °C | 21.4 mOhm |
| DCR maximum @ +25 °C | 23.5 mOhm |
| Rated operating voltage (across inductor) | 15 V |
| Package | 4.6 x 4.6 mm footprint, 2.1 mm height |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
This is the part for automotive DC rails that cannot afford a collapsing inductor: AEC-Q200 qualified, soft saturation, shielded, and rated across the full -55 to +155 °C range. The electrical behaviour matches the commercial moulded family; the qualification and the temperature rating do not.
DCR 21.4 mOhm is the conduction loss: at rated current it dissipates 1.37 W, and that heat has to leave through the terminals and the board.
Isat is the peak current for approximately 30% rolloff at +25 °C. In a multiphase converter the transient peak lands on the inductors before the loop corrects; a soft-saturating core keeps controlling di/dt through exactly that window.
The 155 °C rating is ambient plus self-heating, and the alloy powder core keeps its soft-saturation shape across that range - the transient behaviour at the hot corner is a milder version of the room-temperature curve, not a different part.
EXLA is the automotive moulded family: AEC-Q200 qualified, soft-saturating, shielded, rated to 155 °C - the power-inductor choice for ADAS, body electronics and infotainment rails.
What is the rated operating voltage?
A bias condition for characterisation (per size, 15 V or 40 V across the inductor). It is not an isolation rating.
What does "soft saturation" mean in practice?
The alloy powder core loses inductance gradually with current instead of collapsing. At transient peaks the inductor still limits di/dt - it is the behaviour that keeps a multiphase rail stable through load steps.
Can I substitute it for the commercial EXL part of the same size?
The electrical rows are close, but the qualification, temperature range and the test data are not interchangeable. Substitute on the datasheet row, not on the family name.
Design note: budget the loss at the hot corner with the maximum DCR, and keep the transient peak below Isat with margin - the soft curve forgives, but does not eliminate, saturation.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.