| Parameter | Value |
|---|---|
| Orderable part number | EXLA1V1003-1R0-R |
| OCL | 1 uH ±20% |
| Irms | 23 A |
| Isat (30% rolloff @ +25 °C) | 30 A |
| DCR typical @ +25 °C | 4.5 mOhm |
| DCR maximum @ +25 °C | 4.95 mOhm |
| Rated operating voltage (across inductor) | 40 V |
| Package | 12.2 x 11.3 mm footprint, 3.1 mm height |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
This is the part for automotive DC rails that cannot afford a collapsing inductor: AEC-Q200 qualified, soft saturation, shielded, and rated across the full -55 to +155 °C range. The electrical behaviour matches the commercial moulded family; the qualification and the temperature rating do not.
The typical and the maximum DCR are both quoted for a reason: production spread. A loss budget that has to hold across a build uses 4.5 mOhm as the optimistic case and plans against the maximum.
Isat is defined as the peak current for approximately 30% rolloff at +25 °C. With an alloy powder core the rolloff is soft: past Isat the inductance keeps working, just lower - which is a design resource, not an excuse to run at the limit.
The 155 °C rating is ambient plus self-heating, and the alloy powder core keeps its soft-saturation shape across that range - the transient behaviour at the hot corner is a milder version of the room-temperature curve, not a different part.
EXLA is the automotive moulded family: AEC-Q200 qualified, soft-saturating, shielded, rated to 155 °C - the power-inductor choice for ADAS, body electronics and infotainment rails.
What is the rated operating voltage?
A bias condition for characterisation (per size, 15 V or 40 V across the inductor). It is not an isolation rating.
What is the temperature range?
-55 °C to +155 °C, ambient plus self-temperature rise. The part should not exceed +155 °C under worst-case operating conditions.
Can I substitute it for the commercial EXL part of the same size?
The electrical rows are close, but the qualification, temperature range and the test data are not interchangeable. Substitute on the datasheet row, not on the family name.
Design note: budget the loss at the hot corner with the maximum DCR, and keep the transient peak below Isat with margin - the soft curve forgives, but does not eliminate, saturation.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd