FP1006R2-R08-R at a glance: 85 nH high frequency, high current power inductor, - A Irms, - A Isat, DCR 0.36 mOhm, 10.2 x 8.0 mm body, 6.0 mm tall.
Eaton builds the FP1006R2-R08-R as a high frequency, high current power inductor for 10.2 x 8.0 mm footprints. At 85 nH and - A Irms with 0.36 mOhm of DCR it targets high-current DC-DC stages; the 6.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1006R2-R08-R |
| Inductance, OCL (0 Adc) | 85 nH |
| Inductance, FLL (minimum) | 61 nH |
| Isat2 (20% roll-off @ +125 °C) | 100 A |
| DCR typical @ +20 °C | 0.36 mOhm |
| K-factor (Bp-p = K x L x dI) | 454 |
| Package | 10.2 x 8.0 mm, 6.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 85 nH is measured with no DC in the winding, 61 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Saturation is quoted as 20% roll-off at - A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 0 mW dissipated at - A through 0.36 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 85 nH this is a low-inductance point for the family, which means high ripple for a given input voltage and duty cycle. That is the intent: these parts are chosen when the converter switches fast and the inductor shapes the ripple rather than storing bulk energy.
That makes it the lowest inductance of the 10 parts in this data sheet, with the highest DCR in the series at 0.36 mOhm, which is what the extra turns cost.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 85 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.36 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd