FP1006R2-R12-R at a glance: 120 nH high frequency, high current power inductor, - A Irms, 45 A Isat, DCR 0.36 mOhm, 10.2 x 8.0 mm body, 6.0 mm tall.
The FP1006R2-R12-R is a 10.2 x 8.0 mm high frequency, high current power inductor from Eaton, rated - A Irms at 120 nH and 0.36 mOhm typical DCR. It is a surface-mount part 6.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1006R2-R12-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Inductance, FLL (minimum) | 86 nH |
| Isat (20% roll-off @ +25 °C) | 45 A |
| Isat2 (20% roll-off @ +125 °C) | 71 A |
| DCR typical @ +20 °C | 0.36 mOhm |
| K-factor (Bp-p = K x L x dI) | 454 |
| Package | 10.2 x 8.0 mm, 6.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 120 nH. Put Isat1 through it and the figure falls to 86 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 120 nH number; loop stability and worst-case current belong on the lower one.
Peak current at 20% roll-off is 45 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Irms of - A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.36 mOhm that is roughly 0 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The K-factor of 454 turns ripple into flux: a peak-to-peak swing of 13.5 A gives about 73.5 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 10.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 5 of 10 when the data sheet is sorted by inductance, with the highest DCR in the series at 0.36 mOhm, which is what the extra turns cost.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.36 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.