Eaton FP1007R1-R17-R 60 A SMD Power Inductor, 170 nH
Eaton FP1007R1-R17-R 60 A SMD Power Inductor, 170 nH

Eaton FP1007R1-R17-R 60 A SMD Power Inductor, 170 nH

Share
pEaton FP1007R1-R17-R: 170 nH high frequency, high current power inductor, 60 A Irms, 58 A Isat, DCR 0.29 mOhm, 10.4 x 8.0 mm package./p
    • Product Details
    • Download

    FP1007R1-R17-R at a glance: 170 nH high frequency, high current power inductor, 60 A Irms, 58 A Isat, DCR 0.29 mOhm, 10.4 x 8.0 mm body, 7.5 mm tall.

    Eaton FP1007R1-R17-R High frequency, high current power inductors

    The FP1007R1-R17-R is a 10.4 x 8.0 mm high frequency, high current power inductor from Eaton, rated 60 A Irms at 170 nH and 0.29 mOhm typical DCR. It is a surface-mount part 7.5 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Ratings at a Glance

    Orderable part numberFP1007R1-R17-R
    Inductance, OCL (0 Adc)170 nH
    Inductance, FLL (minimum)122 nH
    Irms (40 °C rise, no core loss)60 A
    Isat (20% roll-off @ +25 °C)58 A
    Isat2 (20% roll-off @ +125 °C)46 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)371
    Package10.4 x 8.0 mm, 7.5 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Two inductance figures are published. 170 nH is measured with no DC in the winding, 122 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    The first Isat column, 58 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    Irms of 60 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.29 mOhm that is roughly 1044 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    The K-factor of 371 turns ripple into flux: a peak-to-peak swing of 17.4 A gives about 109.7 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    The 10.4 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 170 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 7 of 17 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm.

    • Application fit: Servers, Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs).
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    The order of checks that works: compute ripple from 170 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.

    Dimensions and Pad Layout

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1007R1-R17-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message