FP1007R2-R12-R at a glance: 120 nH high frequency, high current power inductor, 51 A Irms, 81 A Isat, DCR 0.48 mOhm, 10.4 x 8.0 mm body, 7.5 mm tall.
Eaton builds the FP1007R2-R12-R as a high frequency, high current power inductor for 10.4 x 8.0 mm footprints. At 120 nH and 51 A Irms with 0.48 mOhm of DCR it targets high-current DC-DC stages; the 7.5 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1007R2-R12-R |
| Inductance, OCL (0 Adc) | 120 nH |
| Inductance, FLL (minimum) | 86 nH |
| Irms (40 °C rise, no core loss) | 51 A |
| Isat (20% roll-off @ +25 °C) | 81 A |
| Isat2 (20% roll-off @ +125 °C) | 65 A |
| DCR typical @ +20 °C | 0.48 mOhm |
| K-factor (Bp-p = K x L x dI) | 368 |
| Package | 10.4 x 8.0 mm, 7.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
120 nH open-circuit, 86 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Peak current at 20% roll-off is 81 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 1248 mW (51 A squared times 0.48 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 107.3 mT for a 24.3 A ripple (K = 368). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 10.4 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 17 when the data sheet is sorted by inductance, with the highest DCR in the series at 0.48 mOhm, which is what the extra turns cost, Irms of 51 A is the bottom of the family.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 120 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.48 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.