Eaton FP1007R3-R12-R - 115 nH Shielded Power Inductor 10.4 x 8.0 mm
Eaton FP1007R3-R12-R - 115 nH Shielded Power Inductor 10.4 x 8.0 mm

Eaton FP1007R3-R12-R - 115 nH Shielded Power Inductor 10.4 x 8.0 mm

Share
pEaton FP1007R3-R12-R: 115 nH high frequency, high current power inductor, 61 A Irms, 94 A Isat, DCR 0.29 mOhm, 10.4 x 8.0 mm package./p
    • Product Details
    • Download

    FP1007R3-R12-R at a glance: 115 nH high frequency, high current power inductor, 61 A Irms, 94 A Isat, DCR 0.29 mOhm, 10.4 x 8.0 mm body, 7.5 mm tall.

    Eaton FP1007R3-R12-R High frequency, high current power inductors

    The FP1007R3-R12-R is a 10.4 x 8.0 mm high frequency, high current power inductor from Eaton, rated 61 A Irms at 115 nH and 0.29 mOhm typical DCR. It is a surface-mount part 7.5 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Electrical Specifications

    Orderable part numberFP1007R3-R12-R
    Inductance, OCL (0 Adc)115 nH
    Inductance, FLL (minimum)83 nH
    Irms (40 °C rise, no core loss)61 A
    Isat (20% roll-off @ +25 °C)94 A
    Isat2 (20% roll-off @ +125 °C)86 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)354
    Package10.4 x 8.0 mm, 7.5 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    At zero bias the winding measures 115 nH. Put Isat1 through it and the figure falls to 83 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 115 nH number; loop stability and worst-case current belong on the lower one.

    The first Isat column, 94 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    The 1079 mW dissipated at 61 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    Core loss needs flux, and flux here is about 114.8 mT for a 28.2 A ripple (K = 354). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Positioning in the FP Range

    The 10.4 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 115 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it the lowest inductance of the 17 parts in this data sheet, and it shares the lowest DCR here at 0.29 mOhm, Irms of 61 A is the top of the family.

    • Application fit: Servers, Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs).
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    The order of checks that works: compute ripple from 115 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    On the board, place the part so the switch-node copper is short and wide. At 0.29 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Mechanical Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1007R3-R12-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why is the saturation current listed at several temperatures?
    Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message