FP1007R6-R15-R at a glance: 150 nH high frequency, high current power inductor, 61 A Irms, 75 A Isat, DCR 0.29 mOhm, 10.5 x 8.0 mm body, 7.0 mm max tall.
The FP1007R6-R15-R is a 10.5 x 8.0 mm high frequency, high current power inductor from Eaton, rated 61 A Irms at 150 nH and 0.29 mOhm typical DCR. It is a surface-mount part 7.0 mm max tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP1007R6-R15-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 108 nH |
| Irms (40 °C rise, no core loss) | 61 A |
| Isat (20% roll-off @ +25 °C) | 75 A |
| Isat2 (20% roll-off @ +100 °C) | 60 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 348.8 |
| Package | 10.5 x 8.0 mm, 7.0 mm max height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
150 nH open-circuit, 108 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Peak current at 20% roll-off is 75 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
The 1079 mW dissipated at 61 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The K-factor of 348.8 turns ripple into flux: a peak-to-peak swing of 22.5 A gives about 117.7 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 10.5 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it the lowest inductance of the 7 parts in this data sheet.
Size the inductor on peak current first, not average. With 150 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.