Eaton FP1008L2-R150-R 150 nH 65 A Saturation Inductor
Eaton FP1008L2-R150-R 150 nH 65 A Saturation Inductor

Eaton FP1008L2-R150-R 150 nH 65 A Saturation Inductor

Share
pEaton FP1008L2-R150-R: 150 nH high frequency, high current power inductor, 65 A Irms, 65 A Isat, DCR 0.17 mOhm, 10.0 x 8.0 mm package./p
    • Product Details
    • Download

    FP1008L2-R150-R at a glance: 150 nH high frequency, high current power inductor, 65 A Irms, 65 A Isat, DCR 0.17 mOhm, 10.0 x 8.0 mm body, 8.0 mm tall.

    Eaton FP1008L2-R150-R High frequency, high current power inductors

    FP1008L2-R150-R is one of Eaton's high frequency, high current power inductor series, 10.0 x 8.0 mm with a 8.0 mm tall profile. Electrically it offers 150 nH at 65 A Irms and 0.17 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.

    Ratings at a Glance

    Orderable part numberFP1008L2-R150-R
    Inductance, OCL (0 Adc)150 nH
    Inductance, FLL (minimum)108 nH
    Irms (40 °C rise, no core loss)65 A
    Isat (20% roll-off @ +25 °C)65 A
    Isat2 (20% roll-off @ +100 °C)57 A
    Isat3 (20% roll-off @ +125 °C)55 A
    DCR typical @ +20 °C0.17 mOhm
    K-factor (Bp-p = K x L x dI)411
    Package10.0 x 8.0 mm, 8.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    The Figures Explained

    150 nH open-circuit, 108 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    Peak current at 20% roll-off is 65 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    Copper loss at the rated current works out at about 718 mW (65 A squared times 0.17 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.

    Flux swing follows Bp-p = K x L x dI. With K = 411 and a ripple of 19.5 A the core sees roughly 120.2 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Series Positioning

    The 10.0 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 2 of 3 when the data sheet is sorted by inductance.

    • Application fit: Servers, Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs).
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Design Notes

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 150 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    On the board, place the part so the switch-node copper is short and wide. At 0.17 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Mechanical Drawing

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1008L2-R150-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    How is the part packed?
    Tape and reel, with the reel quantity stated in the packaging section of the data sheet. The parts are polarised by the terminal marking, so check orientation in the reel before setting up the feeder.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products