Eaton FP1012V2-R150-R 150 nH Power Inductor, 84 A
Eaton FP1012V2-R150-R 150 nH Power Inductor, 84 A

Eaton FP1012V2-R150-R 150 nH Power Inductor, 84 A

Share
pEaton FP1012V2-R150-R: 150 nH high frequency, high current power inductor, 84 A Irms, 83 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm package./p
    • Product Details
    • Download

    FP1012V2-R150-R at a glance: 150 nH high frequency, high current power inductor, 84 A Irms, 83 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.

    Eaton FP1012V2-R150-R High frequency, high current power inductors

    Eaton builds the FP1012V2-R150-R as a high frequency, high current power inductor for 10.0 x 6.0 mm footprints. At 150 nH and 84 A Irms with 0.125 mOhm of DCR it targets high-current DC-DC stages; the 12.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Electrical Specifications

    Orderable part numberFP1012V2-R150-R
    Inductance, OCL (0 Adc)150 nH
    Inductance, FLL (minimum)108 nH
    Irms (40 °C rise, no core loss)84 A
    Isat (20% roll-off @ +25 °C)83 A
    Isat2 (20% roll-off @ +100 °C)70 A
    Isat3 (20% roll-off @ +125 °C)66 A
    DCR typical @ +20 °C0.125 mOhm
    K-factor (Bp-p = K x L x dI)305
    Package10.0 x 6.0 mm, 12.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    Moisture sensitivity levelMSL 1
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Two inductance figures are published. 150 nH is measured with no DC in the winding, 108 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    The first Isat column, 83 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    Irms of 84 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.125 mOhm that is roughly 882 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    Core loss needs flux, and flux here is about 113.9 mT for a 24.9 A ripple (K = 305). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Where This Part Sits in the Range

    The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 11 of 16 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators, Voltage regulator modules (VRMs) and high power density VRMs, Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    The order of checks that works: compute ripple from 150 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.125 mOhm the winding is not the loss, the trace can be.

    Mechanical Drawing

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1012V2-R150-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    What does the R suffix on the part number mean?
    It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message