Eaton FP1012V3-R120-R High Current Inductor, 120 nH 0.125 mOhm
Eaton FP1012V3-R120-R High Current Inductor, 120 nH 0.125 mOhm

Eaton FP1012V3-R120-R High Current Inductor, 120 nH 0.125 mOhm

Share
pEaton FP1012V3-R120-R: 120 nH high frequency, high current power inductor, 84 A Irms, 116 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm package./p
    • Product Details
    • Download

    FP1012V3-R120-R at a glance: 120 nH high frequency, high current power inductor, 84 A Irms, 116 A Isat, DCR 0.125 mOhm, 10.0 x 6.0 mm body, 12.0 mm tall.

    Eaton FP1012V3-R120-R High frequency, high current power inductors

    The FP1012V3-R120-R is a 10.0 x 6.0 mm high frequency, high current power inductor from Eaton, rated 84 A Irms at 120 nH and 0.125 mOhm typical DCR. It is a surface-mount part 12.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Specification Table

    Orderable part numberFP1012V3-R120-R
    Inductance, OCL (0 Adc)120 nH
    Inductance, FLL (minimum)86 nH
    Irms (40 °C rise, no core loss)84 A
    Isat (20% roll-off @ +25 °C)116 A
    Isat2 (20% roll-off @ +100 °C)96 A
    Isat3 (20% roll-off @ +125 °C)89 A
    DCR typical @ +20 °C0.125 mOhm
    K-factor (Bp-p = K x L x dI)305
    Package10.0 x 6.0 mm, 12.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    Moisture sensitivity levelMSL 1
    RoHSCompliant (-R suffix)

    The Figures Explained

    Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    The first Isat column, 116 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    Irms of 84 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.125 mOhm that is roughly 882 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    Core loss needs flux, and flux here is about 127.4 mT for a 34.8 A ripple (K = 305). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Where This Part Sits in the Range

    The 10.0 x 6.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 9 of 16 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators, Voltage regulator modules (VRMs) and high power density VRMs, Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Design Notes

    The order of checks that works: compute ripple from 120 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.125 mOhm the winding is not the loss, the trace can be.

    Outline Drawing

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1012V3-R120-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.