FP1107R1-R23-R at a glance: 230 nH high frequency, high current power inductor, 55 A Irms, 45 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.
Eaton builds the FP1107R1-R23-R as a high frequency, high current power inductor for 11.2 x 8.0 mm footprints. At 230 nH and 55 A Irms with 0.29 mOhm of DCR it targets high-current DC-DC stages; the 7.5 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1107R1-R23-R |
| Inductance, OCL (0 Adc) | 230 nH |
| Inductance, FLL (minimum) | 166 nH |
| Irms (40 °C rise, no core loss) | 55 A |
| Isat (20% roll-off @ +25 °C) | 45 A |
| Isat4 (20% roll-off @ +125 °C) | 36 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 361.1 |
| Package | 11.2 x 8.0 mm, 7.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 230 nH. Put Isat1 through it and the figure falls to 166 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 230 nH number; loop stability and worst-case current belong on the lower one.
Peak current at 20% roll-off is 45 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 877 mW (55 A squared times 0.29 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 112.1 mT for a 13.5 A ripple (K = 361.1). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 230 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 11 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.
The order of checks that works: compute ripple from 230 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
How is the part packed?
Tape and reel, with the reel quantity stated in the packaging section of the data sheet. The parts are polarised by the terminal marking, so check orientation in the reel before setting up the feeder.