Eaton FP1107R1-R40-R - 400 nH Shielded Power Inductor 11.2 x 8.0 mm
Eaton FP1107R1-R40-R - 400 nH Shielded Power Inductor 11.2 x 8.0 mm

Eaton FP1107R1-R40-R - 400 nH Shielded Power Inductor 11.2 x 8.0 mm

Share
pEaton FP1107R1-R40-R: 400 nH high frequency, high current power inductor, 55 A Irms, 25 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm package./p
    • Product Details
    • Download

    FP1107R1-R40-R at a glance: 400 nH high frequency, high current power inductor, 55 A Irms, 25 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.

    Eaton FP1107R1-R40-R High frequency, high current power inductors

    FP1107R1-R40-R is one of Eaton's high frequency, high current power inductor series, 11.2 x 8.0 mm with a 7.5 mm tall profile. Electrically it offers 400 nH at 55 A Irms and 0.29 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.

    Specification Table

    Orderable part numberFP1107R1-R40-R
    Inductance, OCL (0 Adc)400 nH
    Inductance, FLL (minimum)288 nH
    Irms (40 °C rise, no core loss)55 A
    Isat (20% roll-off @ +25 °C)25 A
    Isat4 (20% roll-off @ +125 °C)20 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)361.1
    Package11.2 x 8.0 mm, 7.5 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    Moisture sensitivity levelMSL 1
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Two inductance figures are published. 400 nH is measured with no DC in the winding, 288 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    Peak current at 20% roll-off is 25 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    Irms of 55 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.29 mOhm that is roughly 877 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.

    Flux swing follows Bp-p = K x L x dI. With K = 361.1 and a ripple of 7.5 A the core sees roughly 108.3 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.

    Where This Part Sits in the Range

    The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 400 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.

    That makes it part 17 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.

    • Application fit: Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs), Server and desktop.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing It Into a Design

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 400 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.

    Dimensions and Pad Layout

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1107R1-R40-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products