FP1107R5-R230-R at a glance: 230 nH high frequency, high current power inductor, 55 A Irms, 45 A Isat, DCR 0.29 mOhm, 11.2 x 8.0 mm body, 7.5 mm tall.
Eaton FP1107R5-R230-R is a high frequency, high current power inductor in a 11.2 x 8.0 mm surface-mount package. It carries 230 nH of open-circuit inductance with 55 A Irms and a typical DCR of 0.29 mOhm, which places it in the switching stage of a multi-phase regulator rather than in bulk energy storage. The body is 7.5 mm tall and rated from -40 °C to +125 °C.
| Orderable part number | FP1107R5-R230-R |
| Inductance, OCL (0 Adc) | 230 nH |
| Inductance, FLL (minimum) | 166 nH |
| Irms (40 °C rise, no core loss) | 55 A |
| Isat (20% roll-off @ +25 °C) | 45 A |
| Isat4 (20% roll-off @ +125 °C) | 36 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 361.1 |
| Package | 11.2 x 8.0 mm, 7.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 230 nH. Put Isat1 through it and the figure falls to 166 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 230 nH number; loop stability and worst-case current belong on the lower one.
Peak current at 20% roll-off is 45 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 877 mW (55 A squared times 0.29 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Flux swing follows Bp-p = K x L x dI. With K = 361.1 and a ripple of 13.5 A the core sees roughly 112.1 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 11.2 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 230 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 11 of 22 when the data sheet is sorted by inductance, and it shares the lowest DCR here at 0.29 mOhm, Irms of 55 A is the top of the family.
The order of checks that works: compute ripple from 230 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd