
FP1108B1-R180-R at a glance: 180 nH high frequency, high current power inductor, 40 A Irms, 63 A Isat, DCR 0.29 mOhm, 11.6 x 8.0 mm body, 8.0 mm tall.
Eaton builds the FP1108B1-R180-R as a high frequency, high current power inductor for 11.6 x 8.0 mm footprints. At 180 nH and 40 A Irms with 0.29 mOhm of DCR it targets high-current DC-DC stages; the 8.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1108B1-R180-R |
| Inductance, OCL (0 Adc) | 180 nH |
| Inductance, FLL (minimum) | 130 nH |
| Irms (40 °C rise, no core loss) | 40 A |
| Isat (20% roll-off @ +25 °C) | 63 A |
| Isat2 (20% roll-off @ +125 °C) | 55 A |
| Isat3 (20% roll-off @ +25 °C) | 50 A |
| DCR typical @ +20 °C | 0.29 mOhm |
| K-factor (Bp-p = K x L x dI) | 349 |
| Package | 11.6 x 8.0 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
180 nH open-circuit, 130 nH at full load: that is a 28% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.
Saturation is quoted as 20% roll-off at 63 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 464 mW dissipated at 40 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
Flux swing follows Bp-p = K x L x dI. With K = 349 and a ripple of 18.9 A the core sees roughly 118.7 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
The 11.6 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 180 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
The order of checks that works: compute ripple from 180 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd