FP1108L1-R105-R at a glance: 105 nH high frequency, high current power inductor, 64 A Irms, 81 A Isat, DCR 0.1 mOhm, 11.0 x 8.2 mm body, 8.3 mm tall.
FP1108L1-R105-R is one of Eaton's high frequency, high current power inductor series, 11.0 x 8.2 mm with a 8.3 mm tall profile. Electrically it offers 105 nH at 64 A Irms and 0.1 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1108L1-R105-R |
| Inductance, OCL (0 Adc) | 105 nH |
| Inductance, FLL (minimum) | 76 nH |
| Irms (40 °C rise, no core loss) | 64 A |
| Isat (20% roll-off @ +25 °C) | 81 A |
| Isat2 (20% roll-off @ +75 °C) | 77 A |
| Isat3 (20% roll-off @ +100 °C) | 72 A |
| DCR typical @ +20 °C | 0.1 mOhm |
| K-factor (Bp-p = K x L x dI) | 422 |
| Package | 11.0 x 8.2 mm, 8.3 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 105 nH. Put Isat1 through it and the figure falls to 76 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 105 nH number; loop stability and worst-case current belong on the lower one.
Saturation is quoted as 20% roll-off at 81 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Irms of 64 A is a thermal rating: the current that lifts the part about 40 °C with no core loss counted. Into 0.1 mOhm that is roughly 410 mW of copper loss, which is where the rise comes from. Add core loss and the usable DC current falls below the tabulated value.
The K-factor of 422 turns ripple into flux: a peak-to-peak swing of 24.3 A gives about 107.7 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 11.0 x 8.2 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 105 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it the lowest inductance of the 4 parts in this data sheet, and it shares the lowest DCR here at 0.1 mOhm, Irms of 64 A is the top of the family.
The order of checks that works: compute ripple from 105 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
On the board, place the part so the switch-node copper is short and wide. At 0.1 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd