Eaton FP1108L4-R180-R - 180 nH Shielded Power Inductor 11.0 x 8.0 mm
Eaton FP1108L4-R180-R - 180 nH Shielded Power Inductor 11.0 x 8.0 mm

Eaton FP1108L4-R180-R - 180 nH Shielded Power Inductor 11.0 x 8.0 mm

Share
pEaton FP1108L4-R180-R: 180 nH high frequency, high current power inductor, 91 A Irms, 33 A Isat, DCR 0.05 mOhm, 11.0 x 8.0 mm package./p
    • Product Details
    • Download

    FP1108L4-R180-R at a glance: 180 nH high frequency, high current power inductor, 91 A Irms, 33 A Isat, DCR 0.05 mOhm, 11.0 x 8.0 mm body, 8.0 mm tall.

    Eaton FP1108L4-R180-R High frequency, high current power inductors

    The FP1108L4-R180-R is a 11.0 x 8.0 mm high frequency, high current power inductor from Eaton, rated 91 A Irms at 180 nH and 0.05 mOhm typical DCR. It is a surface-mount part 8.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Electrical Specifications

    Orderable part numberFP1108L4-R180-R
    Inductance, OCL (0 Adc)180 nH
    Inductance, FLL (minimum)129 nH
    Irms (40 °C rise, no core loss)91 A
    Isat (20% roll-off @ +25 °C)33 A
    Isat2 (20% roll-off @ +100 °C)28 A
    Isat3 (20% roll-off @ +125 °C)26 A
    DCR typical @ +20 °C0.05 mOhm
    K-factor (Bp-p = K x L x dI)552
    Package11.0 x 8.0 mm, 8.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    At zero bias the winding measures 180 nH. Put Isat1 through it and the figure falls to 129 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 180 nH number; loop stability and worst-case current belong on the lower one.

    Peak current at 20% roll-off is 33 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    The 414 mW dissipated at 91 A through 0.05 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    Core loss needs flux, and flux here is about 98.4 mT for a 9.9 A ripple (K = 552). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Positioning in the FP Range

    The 11.0 x 8.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 180 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it the highest inductance of the 4 parts in this data sheet.

    • Application fit: Servers, Multi-phase and Vcore regulators, Voltage Regulator Modules (VRMs).
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Size the inductor on peak current first, not average. With 180 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    On the board, place the part so the switch-node copper is short and wide. At 0.05 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Mechanical Drawing

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1108L4-R180-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Shenzhen Gaorunxin Technology Co., Ltd