FP1110V2-R150-R at a glance: 150 nH high frequency, high current power inductor, 61 A Irms, 89 A Isat, DCR 0.18 mOhm, 11.0 x 10.0 mm body, 9.5 mm tall.
Eaton builds the FP1110V2-R150-R as a high frequency, high current power inductor for 11.0 x 10.0 mm footprints. At 150 nH and 61 A Irms with 0.18 mOhm of DCR it targets high-current DC-DC stages; the 9.5 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1110V2-R150-R |
| Inductance, OCL (0 Adc) | 150 nH |
| Inductance, FLL (minimum) | 108 nH |
| Irms (40 °C rise, no core loss) | 61 A |
| Isat (20% roll-off @ +100 °C) | 89 A |
| Isat2 (20% roll-off @ +100 °C) | 70 A |
| DCR typical @ +20 °C | 0.18 mOhm |
| K-factor (Bp-p = K x L x dI) | 328 |
| Package | 11.0 x 10.0 mm, 9.5 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| Moisture sensitivity level | MSL 1 |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 150 nH is measured with no DC in the winding, 108 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Saturation is quoted as 20% roll-off at 89 A at +100 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 670 mW dissipated at 61 A through 0.18 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
The K-factor of 328 turns ripple into flux: a peak-to-peak swing of 26.7 A gives about 131.4 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
The 11.0 x 10.0 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 150 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it the lowest inductance of the 11 parts in this data sheet, and it shares the lowest DCR here at 0.18 mOhm.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 150 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.18 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd