FP1206R1-R25-R at a glance: 250 nH high frequency, high current power inductor, 50 A Irms, 43 A Isat, DCR 0.43 mOhm, 8.0 x 12.0 mm body, 6.0 mm tall.
Eaton builds the FP1206R1-R25-R as a high frequency, high current power inductor for 8.0 x 12.0 mm footprints. At 250 nH and 50 A Irms with 0.43 mOhm of DCR it targets high-current DC-DC stages; the 6.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.
| Orderable part number | FP1206R1-R25-R |
| Inductance, OCL (0 Adc) | 250 nH |
| Inductance, FLL (minimum) | 180 nH |
| Irms (40 °C rise, no core loss) | 50 A |
| Isat (20% roll-off @ +25 °C) | 43 A |
| Isat2 (20% roll-off @ +125 °C) | 32 A |
| DCR typical @ +20 °C | 0.43 mOhm |
| K-factor (Bp-p = K x L x dI) | 358 |
| Package | 8.0 x 12.0 mm, 6.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Two inductance figures are published. 250 nH is measured with no DC in the winding, 180 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.
Peak current at 20% roll-off is 43 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 1075 mW (50 A squared times 0.43 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Flux swing follows Bp-p = K x L x dI. With K = 358 and a ripple of 12.9 A the core sees roughly 115.5 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
At 8.0 x 12.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 250 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 3 of 5 when the data sheet is sorted by inductance.
The order of checks that works: compute ripple from 250 nH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
On the board, place the part so the switch-node copper is short and wide. At 0.43 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.