FP1206R1-R30-R at a glance: 300 nH high frequency, high current power inductor, 50 A Irms, 34 A Isat, DCR 0.43 mOhm, 8.0 x 12.0 mm body, 6.0 mm tall.
FP1206R1-R30-R is one of Eaton's high frequency, high current power inductor series, 8.0 x 12.0 mm with a 6.0 mm tall profile. Electrically it offers 300 nH at 50 A Irms and 0.43 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1206R1-R30-R |
| Inductance, OCL (0 Adc) | 300 nH |
| Inductance, FLL (minimum) | 216 nH |
| Irms (40 °C rise, no core loss) | 50 A |
| Isat (20% roll-off @ +25 °C) | 34 A |
| Isat2 (20% roll-off @ +125 °C) | 26 A |
| DCR typical @ +20 °C | 0.43 mOhm |
| K-factor (Bp-p = K x L x dI) | 358 |
| Package | 8.0 x 12.0 mm, 6.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
At zero bias the winding measures 300 nH. Put Isat1 through it and the figure falls to 216 nH, about 28% lower, because the ferrite is partly saturated. Ripple calculations belong on the 300 nH number; loop stability and worst-case current belong on the lower one.
Saturation is quoted as 20% roll-off at 34 A at +25 °C. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
The 1075 mW dissipated at 50 A through 0.43 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
Core loss needs flux, and flux here is about 109.5 mT for a 10.2 A ripple (K = 358). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
At 8.0 x 12.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 300 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 4 of 5 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 300 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.43 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
What does the R suffix on the part number mean?
It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.