Eaton FP1208R1-R23-R - 230 nH Shielded Power Inductor 12.0 x 8.0 mm
Eaton FP1208R1-R23-R - 230 nH Shielded Power Inductor 12.0 x 8.0 mm

Eaton FP1208R1-R23-R - 230 nH Shielded Power Inductor 12.0 x 8.0 mm

Share
pEaton FP1208R1-R23-R: 230 nH high frequency, high current power inductor, 50 A Irms, 61 A Isat, DCR 0.29 mOhm, 12.0 x 8.0 mm package./p
    • Product Details
    • Download

    FP1208R1-R23-R at a glance: 230 nH high frequency, high current power inductor, 50 A Irms, 61 A Isat, DCR 0.29 mOhm, 12.0 x 8.0 mm body, 8.0 mm tall.

    Eaton FP1208R1-R23-R High frequency, high current power inductors

    Eaton builds the FP1208R1-R23-R as a high frequency, high current power inductor for 12.0 x 8.0 mm footprints. At 230 nH and 50 A Irms with 0.29 mOhm of DCR it targets high-current DC-DC stages; the 8.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Key Specifications

    Orderable part numberFP1208R1-R23-R
    Inductance, OCL (0 Adc)230 nH
    Inductance, FLL (minimum)176 nH
    Irms (40 °C rise, no core loss)50 A
    Isat (20% roll-off @ +25 °C)61 A
    Isat2 (20% roll-off @ +85 °C)53 A
    Isat3 (20% roll-off @ +125 °C)50 A
    DCR typical @ +20 °C0.29 mOhm
    K-factor (Bp-p = K x L x dI)283
    Package12.0 x 8.0 mm, 8.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    230 nH open-circuit, 176 nH at full load: that is a 23% roll-off purely from DC bias, before temperature enters the picture. Use the biased figure when you check peak current against saturation, and the unbiased one when you size the ripple.

    Peak current at 20% roll-off is 61 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    The 725 mW dissipated at 50 A through 0.29 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    Core loss needs flux, and flux here is about 119.1 mT for a 18.3 A ripple (K = 283). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Series Positioning

    At 12.0 x 8.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 230 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 4 of 5 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing It Into a Design

    Size the inductor on peak current first, not average. With 230 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 0.29 mOhm the winding is not the loss, the trace can be.

    Mechanical Drawing

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1208R1-R23-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    What does the R suffix on the part number mean?
    It marks RoHS compliance and is part of the orderable number. The characters before it identify body size, version (DCR bin) and inductance in nanohenries: for example FP1007R1-R12-R is the 10 x 7 mm body, R1 version, 120 nH.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products