FP1308-R21-R at a glance: 210 nH high frequency, high current power inductor, 68 A Irms, 72 A Isat, DCR 0.2 mOhm, 13.7 x 12.9 mm body, 8.0 mm tall.
FP1308-R21-R is one of Eaton's high frequency, high current power inductor series, 13.7 x 12.9 mm with a 8.0 mm tall profile. Electrically it offers 210 nH at 68 A Irms and 0.2 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP1308-R21-R |
| Inductance, OCL (0 Adc) | 210 nH |
| Irms (40 °C rise, no core loss) | 68 A |
| Isat (20% roll-off @ +25 °C) | 72 A |
| DCR typical @ +20 °C | 0.2 mOhm |
| DCR maximum @ +20 °C | 0.24 mOhm |
| K-factor (Bp-p = K x L x dI) | 21.3 |
| Package | 13.7 x 12.9 mm, 8.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +125 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
210 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Peak current at 20% roll-off is 72 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
The 925 mW dissipated at 68 A through 0.2 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.
Flux swing follows Bp-p = K x L x dI. With K = 21.3 and a ripple of 21.6 A the core sees roughly 9.7 mT, which is the number to put into the core-loss curve before you trust a 40 °C rise estimate.
At 13.7 x 12.9 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 210 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it part 2 of 5 when the data sheet is sorted by inductance.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 210 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
On the board, place the part so the switch-node copper is short and wide. At 0.2 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Is this part AEC-Q200 qualified?
No. The FP, FPT and FPV families are commercial-grade parts rated for the operating temperature range in the table. For automotive work Eaton uses the EXLA and DRA families, which carry AEC-Q200 qualification and a wider temperature range.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.