Eaton FP1308-R44-R High Current Inductor, 440 nH 0.2 mOhm
Eaton FP1308-R44-R High Current Inductor, 440 nH 0.2 mOhm

Eaton FP1308-R44-R High Current Inductor, 440 nH 0.2 mOhm

Share
pEaton FP1308-R44-R: 440 nH high frequency, high current power inductor, 68 A Irms, 32 A Isat, DCR 0.2 mOhm, 13.7 x 12.9 mm package./p
    • Product Details
    • Download

    FP1308-R44-R at a glance: 440 nH high frequency, high current power inductor, 68 A Irms, 32 A Isat, DCR 0.2 mOhm, 13.7 x 12.9 mm body, 8.0 mm tall.

    Eaton FP1308-R44-R High frequency, high current power inductors

    Eaton builds the FP1308-R44-R as a high frequency, high current power inductor for 13.7 x 12.9 mm footprints. At 440 nH and 68 A Irms with 0.2 mOhm of DCR it targets high-current DC-DC stages; the 8.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +125 °C.

    Ratings at a Glance

    Orderable part numberFP1308-R44-R
    Inductance, OCL (0 Adc)440 nH
    Irms (40 °C rise, no core loss)68 A
    Isat (20% roll-off @ +25 °C)32 A
    DCR typical @ +20 °C0.2 mOhm
    DCR maximum @ +20 °C0.24 mOhm
    K-factor (Bp-p = K x L x dI)21.4
    Package13.7 x 12.9 mm, 8.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Only the open-circuit value, 440 nH, is tabulated here. With DC in the winding the core will show less, so treat 440 nH as a ceiling rather than an operating value.

    The first Isat column, 32 A at +25 °C, is the peak the part takes at 20% roll-off. Note the temperature: run the same part in a hot enclosure and the usable peak drops, which is why the data sheet prints more than one column.

    The 925 mW dissipated at 68 A through 0.2 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    Core loss needs flux, and flux here is about 9 mT for a 9.6 A ripple (K = 21.4). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.

    Positioning in the FP Range

    At 13.7 x 12.9 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 440 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.

    That makes it the highest inductance of the 5 parts in this data sheet.

    • Application fit: Voltage regulator modules (VRMs) for servers and microprocessors, Multi-phase buck inductors, High frequency, high current switching power supplies.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Putting It to Work

    Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 440 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.

    On the board, place the part so the switch-node copper is short and wide. At 0.2 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Outline Drawing

    The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

    Eaton FP1308-R44-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Shenzhen Gaorunxin Technology Co., Ltd