Eaton FP1505R1-R12-R High Current Inductor, 120 nH 0.47 mOhm
Eaton FP1505R1-R12-R High Current Inductor, 120 nH 0.47 mOhm

Eaton FP1505R1-R12-R High Current Inductor, 120 nH 0.47 mOhm

Share
pEaton FP1505R1-R12-R: 120 nH high frequency, high current power inductor, 53 A Irms, 87 A Isat, DCR 0.47 mOhm, 7.0 x 15.0 mm package./p
    • Product Details
    • Download

    FP1505R1-R12-R at a glance: 120 nH high frequency, high current power inductor, 53 A Irms, 87 A Isat, DCR 0.47 mOhm, 7.0 x 15.0 mm body, 5.0 mm tall.

    Eaton FP1505R1-R12-R High frequency, high current power inductors

    The FP1505R1-R12-R is a 7.0 x 15.0 mm high frequency, high current power inductor from Eaton, rated 53 A Irms at 120 nH and 0.47 mOhm typical DCR. It is a surface-mount part 5.0 mm tall, operating from -40 °C to +125 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.

    Ratings at a Glance

    Orderable part numberFP1505R1-R12-R
    Inductance, OCL (0 Adc)120 nH
    Inductance, FLL (minimum)86 nH
    Irms (40 °C rise, no core loss)53 A
    Isat (20% roll-off @ +25 °C)87 A
    Isat2 (20% roll-off @ +125 °C)75 A
    DCR typical @ +20 °C0.47 mOhm
    K-factor (Bp-p = K x L x dI)356.3
    Package7.0 x 15.0 mm, 5.0 mm height
    Core materialFerrite, magnetically shielded
    Operating temperature-40 °C to +125 °C (ambient plus self-temperature rise)
    RoHSCompliant (-R suffix)

    The Figures Explained

    Two inductance figures are published. 120 nH is measured with no DC in the winding, 86 nH with the winding loaded to Isat1. The gap between them is 28%, and it is the reason a converter that looks well damped at no load can ring at full current.

    Peak current at 20% roll-off is 87 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.

    The 1320 mW dissipated at 53 A through 0.47 mOhm is what sets the 40 °C rise behind the Irms column. Because that figure excludes core loss, a converter running at high frequency with large ripple will heat the part more than the table suggests.

    The K-factor of 356.3 turns ripple into flux: a peak-to-peak swing of 26.1 A gives about 111.6 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.

    Positioning in the FP Range

    At 7.0 x 15.0 mm this is one of the larger FP bodies, aimed at high-current rails where a single phase carries enough current that paralleling smaller parts would cost more board area than it saves. At 120 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.

    That makes it part 2 of 6 when the data sheet is sorted by inductance.

    • Application fit: Multi-phase and Vcore regulators.
    • Construction: ferrite core, magnetically shielded, surface mount, supplied on tape and reel.
    • Temperature: -40 °C to +125 °C, ambient plus self-temperature rise.

    Sizing and Layout Notes

    Size the inductor on peak current first, not average. With 120 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.

    On the board, place the part so the switch-node copper is short and wide. At 0.47 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.

    Outline Drawing

    Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

    Eaton FP1505R1-R12-R mechanical dimensions and recommended pad layout

    Dimensions in millimetres, taken from the Eaton technical data sheet for this series. Tolerances and pad geometry are as drawn; verify against your own footprint before the first production build.

    Frequently Asked Questions

    Can I substitute a lower inductance in the same body?
    Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.

    Why does DCR have both a typical and a maximum figure?
    The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products