FP3-4R7-R at a glance: 4.7 uH high current, low profile inductor, 3.23 A Irms, 3.5 A Isat, DCR 34.9 mOhm, 7.25 x 6.7 mm body, 3.0 mm tall.
The FP3-4R7-R is a 7.25 x 6.7 mm high current, low profile inductor from Eaton, rated 3.23 A Irms at 4.7 uH and 34.9 mOhm typical DCR. It is a surface-mount part 3.0 mm tall, operating from -40 °C to +155 °C, and it is built for the phase node of a buck regulator where the inductor sets ripple and the control loop sets the rest.
| Orderable part number | FP3-4R7-R |
| Inductance, OCL (0 Adc) | 4.7 uH |
| Irms (40 °C rise, no core loss) | 3.23 A |
| Isat | 3.5 A |
| Isat2 | 4.2 A |
| DCR typical @ +20 °C | 34.9 mOhm |
| DCR maximum @ +20 °C | 40 mOhm |
| K-factor (Bp-p = K x L x dI) | 105 |
| Package | 7.25 x 6.7 mm, 3.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
4.7 uH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Saturation is quoted as the quoted roll-off at 3.5 A. That is a convention rather than a cliff: past it the inductance keeps falling, and how quickly depends on how hard the core is driven. Compare your worst-case peak against this number, not the average current.
Copper loss at the rated current works out at about 364 mW (3.23 A squared times 34.9 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
Core loss needs flux, and flux here is about 51.8 mT for a 1.05 A ripple (K = 105). Double the ripple and the flux roughly doubles, but the loss does not - it climbs faster than linearly, which is why pushing ripple up to save inductance is not free.
This is one of the smaller bodies in the FP range. At 7.25 x 6.7 mm it is meant for point-of-load stages and multi-phase VRMs where board area is the binding constraint and current per phase is tens of amps rather than hundreds. At 4.7 uH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 9 of 12 when the data sheet is sorted by inductance, DCR sits between the 1 and 106 mOhm the series covers.
The order of checks that works: compute ripple from 4.7 uH and the duty cycle, add half of it to the DC load to get peak, compare that peak with Isat at the real ambient, and only then look at Irms for heating. Doing it the other way round hides saturation problems.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 34.9 mOhm the winding is not the loss, the trace can be.
Body outline, pad layout and schematic follow. Check the pad drawing against your own footprint library before the first build: these parts are heavy relative to their footprint and the solder joint carries both the current and the mechanical load.

Why is the saturation current listed at several temperatures?
Because the ferrite loses permeability as it heats, so the same winding saturates at a lower current when it is hot. The columns let you read the value at the temperature your board actually runs at instead of scaling a room-temperature number by guesswork.
Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd