FP3-R47-R at a glance: 440 nH high current, low profile inductor, 10.9 A Irms, 11.6 A Isat, DCR 3.05 mOhm, 7.25 x 6.7 mm body, 3.0 mm tall.
Eaton builds the FP3-R47-R as a high current, low profile inductor for 7.25 x 6.7 mm footprints. At 440 nH and 10.9 A Irms with 3.05 mOhm of DCR it targets high-current DC-DC stages; the 3.0 mm tall body keeps the height budget in check, and the part is rated from -40 °C to +155 °C.
| Orderable part number | FP3-R47-R |
| Inductance, OCL (0 Adc) | 440 nH |
| Irms (40 °C rise, no core loss) | 10.9 A |
| Isat | 11.6 A |
| Isat2 | 14.9 A |
| DCR typical @ +20 °C | 3.05 mOhm |
| DCR maximum @ +20 °C | 3.67 mOhm |
| K-factor (Bp-p = K x L x dI) | 344 |
| Package | 7.25 x 6.7 mm, 3.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -40 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
440 nH is the unbiased inductance. The data sheet does not publish a separate full-load figure for this part, so leave margin when you compute ripple at rated current.
Peak current at the quoted roll-off is 11.6 A. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 362 mW (10.9 A squared times 3.05 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The K-factor of 344 turns ripple into flux: a peak-to-peak swing of 3.48 A gives about 52.7 mT peak in the core. Read the material loss curve at that flux and your switching frequency to get the loss term Irms leaves out.
This is one of the smaller bodies in the FP range. At 7.25 x 6.7 mm it is meant for point-of-load stages and multi-phase VRMs where board area is the binding constraint and current per phase is tens of amps rather than hundreds. At 440 nH this sits at the high-inductance end of the family. Ripple is small and core loss with it, but there is less headroom before saturation, because saturation current falls as inductance rises in the same can.
That makes it part 3 of 12 when the data sheet is sorted by inductance, DCR sits between the 1 and 106 mOhm the series covers.
Start from ripple: dI = (Vin - Vout) x D / (L x fsw). With 440 nH and your switching frequency that gives peak current, and the peak is what has to stay under the Isat column for the temperature inside the enclosure. Then check the DC term against Irms.
Two layout points matter with a part this size. Keep the input capacitor loop short, because the switch node is the main source of radiated noise and the inductor will not fix it. And give the pads enough copper: at 3.05 mOhm the winding is not the loss, the trace can be.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.