FP4-200-R at a glance: 200 nH high current power inductor, 40 A Irms, 30 A Isat, DCR 0.38 mOhm, 10.2 x 6.8 mm body, 5.0 mm tall.
FP4-200-R is one of Eaton's high current power inductor series, 10.2 x 6.8 mm with a 5.0 mm tall profile. Electrically it offers 200 nH at 40 A Irms and 0.38 mOhm typical DCR, which is the combination you want when the rail carries tens of amps and the board has no room for a larger can.
| Orderable part number | FP4-200-R |
| Inductance, OCL (0 Adc) | 200 nH |
| Irms (40 °C rise, no core loss) | 40 A |
| Isat (20% roll-off @ +25 °C) | 30 A |
| DCR typical @ +20 °C | 0.38 mOhm |
| DCR maximum @ +20 °C | 0.65 mOhm |
| Volt-microsecond rating | 1.33 V-us |
| Package | 10.2 x 6.8 mm, 5.0 mm height |
| Core material | Ferrite, magnetically shielded |
| Operating temperature | -45 °C to +155 °C (ambient plus self-temperature rise) |
| RoHS | Compliant (-R suffix) |
Only the open-circuit value, 200 nH, is tabulated here. With DC in the winding the core will show less, so treat 200 nH as a ceiling rather than an operating value.
Peak current at 20% roll-off is 30 A at +25 °C. If your ripple is large the peak can sit well above the DC operating point, so check the sum of DC plus half the ripple, not the DC figure on its own.
Copper loss at the rated current works out at about 608 mW (40 A squared times 0.38 mOhm). That is the term the Irms rating measures. The missing term is core loss, and at a few hundred kilohertz it can be the larger of the two.
The data sheet for this part does not publish a K-factor, so core loss has to come from the loss curve rather than from a formula. If the ripple is large, measure it on the bench rather than assuming the 40 °C Irms margin covers it.
The 10.2 x 6.8 mm body sits in the middle of the FP range: wide enough for a winding with low DCR, compact enough to place next to the switching stage without a long loop back to the input capacitors. At 200 nH this is mid-range for the body: moderate ripple, DCR still low, and comfortable operation across most of the switching-frequency range the data sheet quotes.
That makes it the highest inductance of the 5 parts in this data sheet, Irms of 40 A is the top of the family.
Size the inductor on peak current first, not average. With 200 nH the ripple can be a large fraction of the DC term at low inductance, so the peak may be well above the load current - and saturation cares about the peak.
On the board, place the part so the switch-node copper is short and wide. At 0.38 of DCR the component is not the resistive bottleneck; the trace and the vias usually are. Thermal vias under the body help more than a bigger copper pour further away.
The drawing below is taken from the Eaton data sheet for this series: body outline, recommended pad layout and winding schematic. Pad geometry matters more than usual here, because the terminals are large and the body sits low, so an undersized pad wicks solder and lifts the part off the plane.

Why does DCR have both a typical and a maximum figure?
The typical value is what the winding measures in production, the maximum is the limit the part is guaranteed to stay under. Size conduction loss on the maximum, because that is the worst case across a production run and over temperature.
Can I substitute a lower inductance in the same body?
Only after checking saturation. Lower inductance means higher ripple and a higher peak current for the same DC load. The part with less inductance usually has more saturation headroom, but the ripple penalty is real, so recalculate peak current before substituting.