Eaton GLD-3/4 is a 750 mA pin-indicating fast-acting fuse in a 6.3 x 32 mm body, 125 Vac with a 10,000 A interrupting rating.
    • Product Details
    • Download

    Eaton GLD-3/4 750 mA 125 Vac Pin-Indicating Fast-Acting Fuse

    At 750 mA, GLD-3/4 is the rating most often picked when the measured load lands just under the next step up in the GLD range.

    Core Specifications

    ParameterValue
    Manufacturer / SeriesEaton / GLD Series
    Orderable part numberGLD-3/4 (carton of 100)
    Current rating0.75 A (1/2 A)
    Voltage rating125 Vac
    Interrupting rating10,000 A
    Approval basisUL Listed + CSA Certified
    Indicating pinalbaloy-plated
    Body1/4 x 1-1/4 in (6.3 x 32 mm) body with albaloy-plated indicating pin
    Fuse typenon-time-delay (fast acting), pin indicating
    AgencyUL Listed guide JDYX file E19180 (1/2-5 A); UL Recognized guide JDYX2 file E19180 (6 A, 10-15 A); CSA Certified class 1422-01 file 53787 (1/2-5 A); CE
    Environmentalno RoHS or halogen-free claim is made on this datasheet

    At 750 mA

    • Interruption. 10,000 A at the rated voltage is what this part is tested to clear. Above that the enclosure rather than the element decides what happens, so the prospective fault current is part of the application check, not only the load.
    • Position in the range. Sits between GLD-1/2 and GLD-1 in the range. Stepping down to GLD-1/2 trips sooner on light overload but leaves less continuous headroom; GLD-1 trades the other way.

    Where 750 mA Fits

    In practice 750 mA covers desktop and appliance power inlets: single-phase equipment inlets and adapter outputs. Sizing closer than 20 % to the rating leaves no room for the ambient rise inside the enclosure.

    Rating-Specific Notes

    • This rating is 125 Vac / 10,000 A and UL Listed (guide JDYX) plus CSA certified.

    For Procurement

    • Order GLD-3/4. The orderable reference on this page reads GLD-3/4 (carton of 100); the packaging prefix, where the series uses one, goes in front of the part number rather than after it.
    • Agency / compliance for this rating: UL Listed guide JDYX file E19180 (1/2-5 A); UL Recognized guide JDYX2 file E19180 (6 A, 10-15 A); CSA Certified class 1422-01 file 53787 (1/2-5 A); CE.
    • 750 mA is not interchangeable with the neighbouring rating beyond its name: the current, the terminal arrangement and the body dimensions all have to match.

    Frequently Asked Questions

    Will GLD-3/4 carry 750 mA continuously without opening?
    Yes. The published table shows no opening at 100 % of rating, so 750 mA is inside the continuous rating at 25 C. Ambient temperature inside the enclosure, not the nominal current, is what usually forces the next size up.

    What fault current can GLD-3/4 clear?
    10,000 A at rated voltage. That figure assumes a normal branch-circuit source impedance; a stiff transformer feeding the same circuit can exceed it, and then the fuse is no longer the protective device by design.

    Can GLD-3/4 replace the next rating up in an existing design?
    No. Dropping from a higher rating changes both the continuous headroom and the I2t, so a fuse that used to ride through inrush may now open on it. Match current, voltage, I2t and body before substituting.

    Design note: resistance, I2t and voltage-drop values are typical unless identified as ratings. Verify the current data sheet and curves before release.