| Parameter | Rating |
|---|---|
| Part number | GMA-10-R |
| Voltage rating | 125 Vac |
| Element | single element |
| Body | Glass tube, 5 x 20 mm |
| Maximum voltage drop | 110 mV |
| Rated current | 10 A |
| End caps | silver-plated brass 63-315 mA, nickel-plated 500 mA-15 A |
| Typical melting I2t | 280 A²s |
| AC interrupting rating | 200 A at 125 Vac |
| Design standard | UL/CSA 248-14 |
| Typical DC cold resistance | 0.006 Ω |
| Breaking capacity | 35 A at 250 Vac up to 3 A, 10,000 A at 125 Vac, 150-200 A above 6 A |
Common installation contexts include:
What are the ratings of the GMA-10-R?
10 A continuous at 125 Vac, interrupting rating 200 A at 125 Vac.
Is the GMA-10-R fast-acting or time-delay?
It is fast-acting. Expect it to open quickly on overload.
Can the GMA-10-R be used on a higher fault-current circuit?
No — its interrupting rating is 200 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd