Eaton GMA-3-R 3 A Fast-Blow Cartridge Fuse, Glass, 5 x 20 mm
Eaton GMA-3-R 3 A Fast-Blow Cartridge Fuse, Glass, 5 x 20 mm

Eaton GMA-3-R 3 A Fast-Blow Cartridge Fuse, Glass, 5 x 20 mm

Share
pEaton GMA-3-R — 3 A, 250 V, fast-acting glass cartridge fuse, 5 x 20 mm, 100 A at 250 Vac; 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton GMA-3-R 3 A Fast-Blow Cartridge Fuse, Glass, 5 x 20 mm

    The GMA-3-R from Eaton carries 3 A, rated 250 Vac, uses a fast-acting element, in a glass body, measuring 5 x 20 mm.

    Technical Data

    ParameterRating
    Part numberGMA-3-R
    Elementsingle element
    End capssilver-plated brass 63-315 mA, nickel-plated 500 mA-15 A
    BodyGlass tube, 5 x 20 mm
    Design standardUL/CSA 248-14
    Typical melting I2t8.8 A²s
    AC interrupting rating100 A at 250 Vac; 10,000 A at 125 Vac
    Maximum voltage drop215 mV
    Voltage rating250 Vac
    Typical DC cold resistance0.039 Ω
    Rated current3 A

    Practical Notes

    • Interrupting capability is 100 A at 250 Vac; 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Footprint 5 x 20 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 3 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV

    Questions and Answers

    What are the ratings of the GMA-3-R?

    3 A continuous at 250 Vac, interrupting rating 100 A at 250 Vac; 10,000 A at 125 Vac.

    Is the GMA-3-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    What size is the GMA-3-R?

    It measures 5 x 20 mm. Match the holder or clip to this footprint.

    Can the GMA-3-R be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message