Eaton GMA-6-R 6 A Glass Tube Fuse, Fast-Blow, 125 Vac
Eaton GMA-6-R 6 A Glass Tube Fuse, Fast-Blow, 125 Vac

Eaton GMA-6-R 6 A Glass Tube Fuse, Fast-Blow, 125 Vac

Share
pEaton GMA-6-R — 6 A, 125 V, fast-acting glass cartridge fuse, 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton GMA-6-R 6 A Glass Tube Fuse, Fast-Blow, 125 Vac

    Built by Eaton, the GMA-6-R carries 6 A, rated 125 Vac, uses a fast-acting element, in a glass body.

    Technical Data

    ParameterRating
    Part numberGMA-6-R
    AC interrupting rating10,000 A at 125 Vac
    BodyGlass tube, 5 x 20 mm
    Maximum voltage drop180 mV
    Breaking capacity35 A at 250 Vac up to 3 A, 10,000 A at 125 Vac, 150-200 A above 6 A
    Typical DC cold resistance0.017 Ω
    Voltage rating125 Vac
    Typical melting I2t45 A²s
    End capssilver-plated brass 63-315 mA, nickel-plated 500 mA-15 A
    Design standardUL/CSA 248-14
    Elementsingle element
    Rated current6 A

    Selection Notes

    • Interrupting capability is 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 125 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 6 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Q&A

    What are the ratings of the GMA-6-R?

    6 A continuous at 125 Vac, interrupting rating 10,000 A at 125 Vac.

    Is the GMA-6-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the GMA-6-R be used on a higher fault-current circuit?

    No — its interrupting rating is 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message