| Parameter | Rating |
|---|---|
| Part number | GMA-6-R |
| AC interrupting rating | 10,000 A at 125 Vac |
| Body | Glass tube, 5 x 20 mm |
| Maximum voltage drop | 180 mV |
| Breaking capacity | 35 A at 250 Vac up to 3 A, 10,000 A at 125 Vac, 150-200 A above 6 A |
| Typical DC cold resistance | 0.017 Ω |
| Voltage rating | 125 Vac |
| Typical melting I2t | 45 A²s |
| End caps | silver-plated brass 63-315 mA, nickel-plated 500 mA-15 A |
| Design standard | UL/CSA 248-14 |
| Element | single element |
| Rated current | 6 A |
Engineers usually specify it for these duties:
What are the ratings of the GMA-6-R?
6 A continuous at 125 Vac, interrupting rating 10,000 A at 125 Vac.
Is the GMA-6-R fast-acting or time-delay?
It is fast-acting. Expect it to open quickly on overload.
Can the GMA-6-R be used on a higher fault-current circuit?
No — its interrupting rating is 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd