Eaton GMA-8-R 8 A Fast-Acting 5 x 20 mm Glass Fuse
Eaton GMA-8-R 8 A Fast-Acting 5 x 20 mm Glass Fuse

Eaton GMA-8-R 8 A Fast-Acting 5 x 20 mm Glass Fuse

Share
pEaton GMA-8-R — 8 A, 125 V, fast-acting glass cartridge fuse, 5 x 20 mm, 200 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton GMA-8-R 8 A Fast-Acting 5 x 20 mm Glass Fuse

    Built by Eaton, the GMA-8-R carries 8 A, rated 125 Vac, uses a fast-acting element, in a glass body, measuring 5 x 20 mm.

    Technical Data

    ParameterRating
    Part numberGMA-8-R
    Typical melting I2t280 A²s
    Typical DC cold resistance0.009 Ω
    Design standardUL/CSA 248-14
    Rated current8 A
    BodyGlass tube, 5 x 20 mm
    End capssilver-plated brass 63-315 mA, nickel-plated 500 mA-15 A
    Maximum voltage drop110 mV
    Elementsingle element
    Breaking capacity35 A at 250 Vac up to 3 A, 10,000 A at 125 Vac, 150-200 A above 6 A
    AC interrupting rating200 A at 125 Vac
    Voltage rating125 Vac

    Selection Notes

    • Interrupting capability is 200 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Footprint 5 x 20 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 125 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 8 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV
    • surge

    Q&A

    What are the ratings of the GMA-8-R?

    8 A continuous at 125 Vac, interrupting rating 200 A at 125 Vac.

    Is the GMA-8-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    What size is the GMA-8-R?

    It measures 5 x 20 mm. Match the holder or clip to this footprint.

    Can the GMA-8-R be used on a higher fault-current circuit?

    No — its interrupting rating is 200 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message