| Parameter | Rating |
|---|---|
| Part number | GMC-800-R |
| Design standard | UL/CSA 248-14 |
| Body | Glass tube, 5 x 20 mm |
| Element | single element |
| Maximum voltage drop | 290 mV |
| Typical DC cold resistance | 0.18 Ω |
| AC interrupting rating | 35 A at 250 Vac; 10,000 A at 125 Vac |
| Rated current | 800 mA |
| Voltage rating | 250 Vac |
| End caps | nickel-plated brass |
| Typical melting I2t | 0.85 A²s |
Engineers usually specify it for these duties:
What are the ratings of the GMC-800-R?
800 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac; 10,000 A at 125 Vac.
Is the GMC-800-R fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the GMC-800-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.