Eaton HC1-100-R 10.5 uH Foil Power Inductor, 12.8 A
Eaton HC1-100-R 10.5 uH Foil Power Inductor, 12.8 A

Eaton HC1-100-R 10.5 uH Foil Power Inductor, 12.8 A

Share
Eaton HC1-100-R: foil-wound high-current inductor, 10.5 uH ±15%, 12.8 A Irms, Isat 5.3 A, DCR 5.7 mOhm, 13.0 x 10.0 mm.
    • Product Details
    • Download

    Eaton HC1-100-R 10.5 uH Foil Power Inductor, 12.8 A

    HC1-100-R at a glance: foil-wound high-current inductor, 10.5 uH ±15%, 12.8 A Irms, Isat 5.3 A (30% rolloff @ +20 °C), DCR 5.7 mOhm, 13.0 x 10.0 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHC1-100-R
    OCL (open circuit inductance)10.5 uH ±15%
    Irms (DC, 40 °C rise)12.8 A
    Isat (30% rolloff @ +20 °C)5.3 A
    DCR typical @ +20 °C5.7 mOhm
    Volt-time rating (V-us)11
    Package13.0 x 10.0 mm
    Height4.9 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4328

    Dimensions and Pad Layout

    HC1-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4328: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    A foil winding on a ferrite core is the classic answer to a hard combination: several tens of amps, a supply below 5 V, and a switching frequency high enough that skin depth has already eaten into round wire. The flat conductor keeps the window utilisation high, so DCR stays in the fractions of a milliohm.

    Copper loss at the rated current works out to roughly 0.932 W from a typical DCR of 5.7 mOhm at 12.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 30% rolloff @ +20 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    At Isat the part holds about 148 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    Where This Series Fits

    The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.

    Of the 11 values listed for HC1, this is the 11th, in a family covering 0.218 uH to 10.5 uH.

    The next value up in the same family, HC1-7R8-R, gives 7.85 uH at 12.8 A and DCR 5.7 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: foil winding, ferrite core, 13.0 x 10.0 mm body at 4.9 mm.
    • Typical applications: distributed power systems dc-dc converters; general-purpose low voltage supplies; computer systems; servers; industrial equipment; data networking and storage systems.
    • The rated current assumes a 40 °C rise from DC alone. AC ripple raises the winding temperature further, and the derating curves in the data sheet are there for exactly that case.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 5.7 mOhm becomes roughly 8.05 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.

    • At frequencies above a few hundred kilohertz, check the AC resistance rise before assuming the DC figure holds.
    • Keep the peak current inside the saturation boundary with margin for inductance tolerance.
    • Apply the AC derating curve before assuming the 40 °C rise figure holds.

    Frequently Asked Questions

    What does the volt-microsecond column describe?
    It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.

    What does the DCR tolerance mean for paralleling?
    Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.

    Is the rated current a continuous rating?
    It is the DC current that produces a 40 °C rise without core loss. Continuous operation at that current is possible only if the board and the airflow remove the heat; the data sheet derating curves cover AC and core loss.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products