Eaton HC1-1R0-R Foil-Wound Inductor 1.12 uH, Isat 25.4 A
Eaton HC1-1R0-R Foil-Wound Inductor 1.12 uH, Isat 25.4 A

Eaton HC1-1R0-R Foil-Wound Inductor 1.12 uH, Isat 25.4 A

Share
Eaton HC1-1R0-R: foil-wound high-current inductor, 1.12 uH ±15%, 28 A Irms, Isat 25.4 A, DCR 1.23 mOhm, 13.0 x 10.0 mm.
    • Product Details
    • Download

    Eaton HC1-1R0-R Foil-Wound Inductor 1.12 uH, Isat 25.4 A

    HC1-1R0-R at a glance: foil-wound high-current inductor, 1.12 uH ±15%, 28 A Irms, Isat 25.4 A (30% rolloff @ +20 °C), DCR 1.23 mOhm, 13.0 x 10.0 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC1-1R0-R
    OCL (open circuit inductance)1.12 uH ±15%
    Irms (DC, 40 °C rise)28 A
    Isat (30% rolloff @ +20 °C)25.4 A
    DCR typical @ +20 °C1.23 mOhm
    Volt-time rating (V-us)5.49
    Package13.0 x 10.0 mm
    Height4.9 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4328

    Mechanical Drawing

    HC1-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4328: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This part belongs to the HC foil family, built for high-current, low-voltage converters where efficiency is dominated by the copper. Ferrite keeps core loss low at the switching frequency; the foil winding keeps the copper loss low at the DC component. Both halves of the loss budget are addressed in the same body.

    Copper loss at the rated current works out to roughly 0.965 W from a typical DCR of 1.23 mOhm at 28 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 30% rolloff @ +20 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 361 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    What This Family Is For

    The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.

    Within the HC1 family this is value 5 of 11, in a range that runs from 0.218 uH to 10.5 uH.

    The next value up in the same family, HC1-1R7-R, gives 1.66 uH at 22.3 A and DCR 2 mOhm: the extra inductance costs about 5.71 A of rated current.

    • Core material: foil winding, ferrite core, 13.0 x 10.0 mm body at 4.9 mm.
    • Typical applications: distributed power systems dc-dc converters; general-purpose low voltage supplies; computer systems; servers; industrial equipment; data networking and storage systems.
    • The rated current assumes a 40 °C rise from DC alone. AC ripple raises the winding temperature further, and the derating curves in the data sheet are there for exactly that case.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.23 mOhm becomes roughly 1.74 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.

    • Check the millivolt drop at rated current against the converter tolerance window.
    • Keep the peak current inside the saturation boundary with margin for inductance tolerance.
    • Apply the AC derating curve before assuming the 40 °C rise figure holds.

    Frequently Asked Questions

    What does the DCR tolerance mean for paralleling?
    Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.

    What does the DCR tolerance mean for paralleling?
    Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.

    What does the volt-microsecond column describe?
    It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.