| Parameter | Value |
|---|---|
| Orderable part number | HC1-R57-R |
| OCL (open circuit inductance) | 0.572 uH ±15% |
| Irms (DC, 40 °C rise) | 37.8 A |
| Isat (30% rolloff @ +20 °C) | 33.4 A |
| DCR typical @ +20 °C | 0.68 mOhm |
| Volt-time rating (V-us) | 3.66 |
| Package | 13.0 x 10.0 mm |
| Height | 4.9 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4328 |

Drawing reproduced from Eaton Technical Data 4328: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A foil winding on a ferrite core is the classic answer to a hard combination: several tens of amps, a supply below 5 V, and a switching frequency high enough that skin depth has already eaten into round wire. The flat conductor keeps the window utilisation high, so DCR stays in the fractions of a milliohm.
At the rated 37.8 A the winding dissipates about 0.973 W in copper alone, using the typical DCR of 0.68 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Saturation is quoted as 30% rolloff @ +20 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Stored energy at Isat is about 319 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
Within the HC1 family this is value 3 of 11, in a range that runs from 0.218 uH to 10.5 uH.
The next value up in the same family, HC1-R87-R, gives 0.866 uH at 28 A and DCR 1.23 mOhm: the extra inductance costs about 23.4 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.68 mOhm becomes roughly 0.961 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
Is the part suitable for a SEPIC or buck-boost stage?
The inductance and current ratings suit it, but check the AC flux swing: in a buck-boost the inductor carries the full input current continuously, so the core loss is higher than in a buck stage of the same output.
What does the volt-microsecond column describe?
It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.
What does the volt-microsecond column describe?
It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.