| Parameter | Value |
|---|---|
| Orderable part number | HC2-1R0-R |
| Ordering code, tape and reel | HC2-1R0TR-R |
| OCL (open circuit inductance) | 1.15 uH ±20% |
| Irms (DC, 40 °C rise) | 33 A |
| Isat (20% rolloff @ +25 °C) | 42.5 A |
| DCR typical @ +20 °C | 1.3 mOhm |
| Volt-time rating (V-us) | 10.3 |
| Package | 19.2 x 19.0 mm |
| Height | 12.7 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4109 |

Drawing reproduced from Eaton Technical Data 4109: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This part belongs to the HC foil family, built for high-current, low-voltage converters where efficiency is dominated by the copper. Ferrite keeps core loss low at the switching frequency; the foil winding keeps the copper loss low at the DC component. Both halves of the loss budget are addressed in the same body.
With 1.3 mOhm typical, the I-squared-R loss at the full 33 A rating is about 1.42 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 1,039 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
Of the 6 values listed for HC2, this is the 3th, in a family covering 0.52 uH to 6 uH.
The next value up in the same family, HC2-2R2-R, gives 2.00 uH at 24.3 A and DCR 2.3 mOhm: the extra inductance costs about 28.6 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.3 mOhm becomes roughly 1.84 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
What does the DCR tolerance mean for paralleling?
Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.
Is the rated current a continuous rating?
It is the DC current that produces a 40 °C rise without core loss. Continuous operation at that current is possible only if the board and the airflow remove the heat; the data sheet derating curves cover AC and core loss.
What does the volt-microsecond column describe?
It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.