Eaton HC2-2R2-R 2.00 uH High-Current Inductor 2.3 mOhm
Eaton HC2-2R2-R 2.00 uH High-Current Inductor 2.3 mOhm

Eaton HC2-2R2-R 2.00 uH High-Current Inductor 2.3 mOhm

Share
Eaton HC2-2R2-R: foil-wound high-current inductor, 2.00 uH ±20%, 24.3 A Irms, Isat 31.9 A, DCR 2.3 mOhm, 19.2 x 19.0 mm.
    • Product Details
    • Download

    Eaton HC2-2R2-R 2.00 uH High-Current Inductor 2.3 mOhm

    HC2-2R2-R at a glance: foil-wound high-current inductor, 2.00 uH ±20%, 24.3 A Irms, Isat 31.9 A (20% rolloff @ +25 °C), DCR 2.3 mOhm, 19.2 x 19.0 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC2-2R2-R
    Ordering code, tape and reelHC2-2R2TR-R
    OCL (open circuit inductance)2.00 uH ±20%
    Irms (DC, 40 °C rise)24.3 A
    Isat (20% rolloff @ +25 °C)31.9 A
    DCR typical @ +20 °C2.3 mOhm
    Volt-time rating (V-us)13.8
    Package19.2 x 19.0 mm
    Height12.7 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4109

    Dimensions and Pad Layout

    HC2-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4109: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Where a power rail delivers tens of amps at a volt or two, the inductor is effectively a short circuit that happens to store energy. The foil construction here minimises the resistance of that short circuit while the ferrite core holds the inductance, which is why the family is used on distributed power and server-class converters.

    At the rated 24.3 A the winding dissipates about 1.36 W in copper alone, using the typical DCR of 2.3 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 1,018 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    What This Family Is For

    The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.

    In the HC2 line-up this part is number 4 of 6 by inductance, between 0.52 uH and 6 uH.

    The next value up in the same family, HC2-4R7-R, gives 4.55 uH at 17 A and DCR 4.6 mOhm: the extra inductance costs about 16 A of rated current.

    • Core material: metal composite, 19.2 x 19.0 mm body at 12.7 mm.
    • Typical applications: distributed power systems dc-dc converters; general-purpose low voltage supplies; computer systems; servers; point of load (pol) converters; industrial equipment.
    • The rated current assumes a 40 °C rise from DC alone. AC ripple raises the winding temperature further, and the derating curves in the data sheet are there for exactly that case.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.3 mOhm becomes roughly 3.25 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.

    • Leave clearance for the tape-and-reel orientation if the line places by vision.
    • Check the millivolt drop at rated current against the converter tolerance window.
    • Apply the AC derating curve before assuming the 40 °C rise figure holds.

    Frequently Asked Questions

    Is the part suitable for a SEPIC or buck-boost stage?
    The inductance and current ratings suit it, but check the AC flux swing: in a buck-boost the inductor carries the full input current continuously, so the core loss is higher than in a buck stage of the same output.

    What does the DCR tolerance mean for paralleling?
    Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.

    Is the rated current a continuous rating?
    It is the DC current that produces a 40 °C rise without core loss. Continuous operation at that current is possible only if the board and the airflow remove the heat; the data sheet derating curves cover AC and core loss.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products