Eaton HC2LP-R47-R Foil-Wound Inductor 0.52 uH, Isat 63.8 A
Eaton HC2LP-R47-R Foil-Wound Inductor 0.52 uH, Isat 63.8 A

Eaton HC2LP-R47-R Foil-Wound Inductor 0.52 uH, Isat 63.8 A

Share
Eaton HC2LP-R47-R: foil-wound high-current inductor, 0.52 uH ±20%, 52.9 A Irms, Isat 63.8 A, DCR 0.6 mOhm, 19.2 x 19.2 mm.
    • Product Details
    • Download

    Eaton HC2LP-R47-R Foil-Wound Inductor .52 uH, Isat 63.8 A

    HC2LP-R47-R at a glance: foil-wound high-current inductor, .52 uH ±20%, 52.9 A Irms, Isat 63.8 A (20% rolloff @ +25 °C), DCR 0.6 mOhm, 19.2 x 19.2 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC2LP-R47-R
    OCL (open circuit inductance).52 uH ±20%
    Irms (DC, 40 °C rise)52.9 A
    Isat (20% rolloff @ +25 °C)63.8 A
    DCR typical @ +20 °C0.6 mOhm
    Volt-time rating (V-us)6.87
    Package19.2 x 19.2 mm
    Height11.18 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4114

    Mechanical Dimensions & Pad Layout

    HC2LP-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4114: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    The winding in this part is copper foil rather than magnet wire. Foil gives the conductor a wide, flat section, so the high-frequency current crowds into a much larger effective area and the AC resistance stays close to the DC value. On a low-voltage, high-current rail that is the difference between an inductor that runs cool at 300 kHz and one that cooks.

    At the rated 52.9 A the winding dissipates about 1.68 W in copper alone, using the typical DCR of 0.6 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 1,057 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    What This Family Is For

    The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.

    Of the 6 values listed for HC2LP, this is the 1th, in a family covering 0.52 uH to 6 uH.

    Compared with its neighbours in the table, HC2LP-R68-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: ferrite core, 19.2 x 19.2 mm body at 11.18 mm.
    • Typical applications: distributed power systems dc-dc converters; general-purpose low voltage supplies; computer systems; servers; point of load (pol) converters; industrial equipment.
    • The rated current assumes a 40 °C rise from DC alone. AC ripple raises the winding temperature further, and the derating curves in the data sheet are there for exactly that case.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.6 mOhm becomes roughly 0.848 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.

    • Apply the AC derating curve before assuming the 40 °C rise figure holds.
    • At frequencies above a few hundred kilohertz, check the AC resistance rise before assuming the DC figure holds.
    • At frequencies above a few hundred kilohertz, check the AC resistance rise before assuming the DC figure holds.

    Frequently Asked Questions

    Can this replace a powdered-core part of the same value?
    Only if the saturation behaviour is acceptable. Ferrite saturates abruptly compared with a powder core, so the transient margin has to be re-checked even when the inductance and DCR look similar.

    What does the volt-microsecond column describe?
    It is the applied volt-time product that produces a core loss equal to 10 % of the total loss at a 40 °C rise. It is a way to compare core capability between parts at a given frequency.

    What does the DCR tolerance mean for paralleling?
    Parts are not matched for DCR, so two in parallel will not share current exactly. The mismatch is set by the DCR tolerance, and because the DCR is only fractions of a milliohm, a small absolute difference is a large percentage one.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products