| Parameter | Value |
|---|---|
| Orderable part number | HC3-1R0-R |
| OCL (open circuit inductance) | 1.05 uH ±20% |
| Irms (DC, 40 °C rise) | 78 A |
| Isat (20% rolloff @ +25 °C) | 78 A |
| DCR typical @ +20 °C | 0.42 mOhm |
| Volt-time rating (V-us) | 17.3 |
| Package | 30.0 x 25.3 mm |
| Height | 18.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4122 |

Drawing reproduced from Eaton Technical Data 4122: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Where a power rail delivers tens of amps at a volt or two, the inductor is effectively a short circuit that happens to store energy. The foil construction here minimises the resistance of that short circuit while the ferrite core holds the inductance, which is why the family is used on distributed power and server-class converters.
The DCR figure of 0.42 mOhm is what sets the efficiency: at 78 A the winding drops about 0.033 mV and dissipates 2.56 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 3,194 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.
The HC3 family spans 0.5 uH to 6.52 uH; this row sits at position 2 of 7.
One step down the table, HC3-R50-R, sits at 0.50 uH with 78 A and 0.42 mOhm – the lower inductance buys about 22.5 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.42 mOhm becomes roughly 0.593 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.
Is the part suitable for a SEPIC or buck-boost stage?
The inductance and current ratings suit it, but check the AC flux swing: in a buck-boost the inductor carries the full input current continuously, so the core loss is higher than in a buck stage of the same output.
Is the rated current a continuous rating?
It is the DC current that produces a 40 °C rise without core loss. Continuous operation at that current is possible only if the board and the airflow remove the heat; the data sheet derating curves cover AC and core loss.
Why foil instead of round wire?
At high frequency the current crowds into the surface of the conductor. A flat foil presents a wide surface for the same cross-section, so the AC resistance stays closer to the DC value and the winding runs cooler.