Eaton HC3-2R2-R 2.05 uH Ferrite Foil Inductor
Eaton HC3-2R2-R 2.05 uH Ferrite Foil Inductor

Eaton HC3-2R2-R 2.05 uH Ferrite Foil Inductor

Share
Eaton HC3-2R2-R: foil-wound high-current inductor, 2.05 uH ±20%, 55.5 A Irms, Isat 60 A, DCR 0.7 mOhm, 30.0 x 25.3 mm.
    • Product Details
    • Download

    Eaton HC3-2R2-R 2.05 uH Ferrite Foil Inductor

    HC3-2R2-R at a glance: foil-wound high-current inductor, 2.05 uH ±20%, 55.5 A Irms, Isat 60 A (20% rolloff @ +25 °C), DCR 0.7 mOhm, 30.0 x 25.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC3-2R2-R
    OCL (open circuit inductance)2.05 uH ±20%
    Irms (DC, 40 °C rise)55.5 A
    Isat (20% rolloff @ +25 °C)60 A
    DCR typical @ +20 °C0.7 mOhm
    Volt-time rating (V-us)26
    Package30.0 x 25.3 mm
    Height18.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4122

    Mechanical Dimensions & Pad Layout

    HC3-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4122: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This part belongs to the HC foil family, built for high-current, low-voltage converters where efficiency is dominated by the copper. Ferrite keeps core loss low at the switching frequency; the foil winding keeps the copper loss low at the DC component. Both halves of the loss budget are addressed in the same body.

    With 0.7 mOhm typical, the I-squared-R loss at the full 55.5 A rating is about 2.16 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    The core stores roughly 3,690 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    Series Positioning

    The HC foil family covers the low-inductance, very-high-current end of the range: sub-microhenry to a few microhenry, with DC resistance measured in fractions of a milliohm. It is the family to reach for when the rail is a volt or two and the current is tens of amps.

    Within the HC3 family this is value 3 of 7, in a range that runs from 0.5 uH to 6.52 uH.

    One step down the table, HC3-1R0-R, sits at 1.05 uH with 78 A and 0.42 mOhm – the lower inductance buys about 35.5 A of extra current in the same body.

    • Core material: ferrite core, 30.0 x 25.3 mm body at 18.0 mm.
    • Typical applications: distributed power systems dc-dc converters; general-purpose low voltage supplies; computer systems; servers; point of load (pol) converters; industrial equipment.
    • The rated current assumes a 40 °C rise from DC alone. AC ripple raises the winding temperature further, and the derating curves in the data sheet are there for exactly that case.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.7 mOhm becomes roughly 0.989 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: on a low-voltage rail the DCR drop is a real fraction of the output. Compare the millivolt drop at rated current against the converter tolerance before choosing the smallest inductance in the family.

    • Check the millivolt drop at rated current against the converter tolerance window.
    • Check the millivolt drop at rated current against the converter tolerance window.
    • Check the millivolt drop at rated current against the converter tolerance window.

    Frequently Asked Questions

    Is the rated current a continuous rating?
    It is the DC current that produces a 40 °C rise without core loss. Continuous operation at that current is possible only if the board and the airflow remove the heat; the data sheet derating curves cover AC and core loss.

    Can this replace a powdered-core part of the same value?
    Only if the saturation behaviour is acceptable. Ferrite saturates abruptly compared with a powder core, so the transient margin has to be re-checked even when the inductance and DCR look similar.

    Why foil instead of round wire?
    At high frequency the current crowds into the surface of the conductor. A flat foil presents a wide surface for the same cross-section, so the AC resistance stays closer to the DC value and the winding runs cooler.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products