Eaton HC7-4R7-R 4.81 uH High-Current Inductor 9 mOhm
Eaton HC7-4R7-R 4.81 uH High-Current Inductor 9 mOhm

Eaton HC7-4R7-R 4.81 uH High-Current Inductor 9 mOhm

Share
Eaton HC7-4R7-R: powder iron high-current inductor, 4.81 uH ±20%, 9.8 A Irms, Isat 9.2 A, DCR 9 mOhm, 13.8 mm long.
    • Product Details
    • Download

    Eaton HC7-4R7-R 4.81 uH High-Current Inductor 9 mOhm

    HC7-4R7-R at a glance: powder iron high-current inductor, 4.81 uH ±20%, 9.8 A Irms, Isat 9.2 A (15% rolloff), DCR 9 mOhm, 13.8 mm long.

    Key Specifications

    ParameterValue
    Orderable part numberHC7-4R7-R
    OCL (open circuit inductance)4.81 uH ±20%
    Irms (DC, 40 °C rise)9.8 A
    Isat (15% rolloff)9.2 A
    Isat2 (30% rolloff)17.3 A
    DCR typical @ +20 °C9 mOhm
    Volt-time rating (V-us)12.6
    Package13.8 mm long
    Height5.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4116

    Mechanical Dimensions & Pad Layout

    HC7-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4116: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.

    With 9 mOhm typical, the I-squared-R loss at the full 9.8 A rating is about 0.864 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 15% rolloff, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 204 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The second saturation column, 17.3 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC7 family spans 0.22 uH to 4.81 uH; this row sits at position 7 of 7.

    The next value up in the same family, HC7-3R9-R, gives 3.61 uH at 10.4 A and DCR 7.9 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: powder iron core, 13.8 mm long body at 5.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9 mOhm becomes roughly 13.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.

    Frequently Asked Questions

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    Does the inductance drift with age?
    The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products