Eaton HC8-220-R Powder Iron Inductor 21.40 uH, Isat 3.5 A
Eaton HC8-220-R Powder Iron Inductor 21.40 uH, Isat 3.5 A

Eaton HC8-220-R Powder Iron Inductor 21.40 uH, Isat 3.5 A

Share
Eaton HC8-220-R: powder iron high-current inductor, 21.40 uH ±20%, 3.4 A Irms, Isat 3.5 A, DCR 99.5 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-220-R Powder Iron Inductor 21.40 uH, Isat 3.5 A

    HC8-220-R at a glance: powder iron high-current inductor, 21.40 uH ±20%, 3.4 A Irms, Isat 3.5 A (15% rolloff), DCR 99.5 mOhm, 10.9 x 10.4 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC8-220-R
    OCL (open circuit inductance)21.40 uH ±20%
    Irms (DC, 40 °C rise)3.4 A
    Isat (15% rolloff)3.5 A
    Isat2 (30% rolloff)6.2 A
    DCR typical @ +20 °C99.5 mOhm
    Volt-time rating (V-us)18.6
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Mechanical Drawing

    HC8-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.

    The DCR figure of 99.5 mOhm is what sets the efficiency: at 3.4 A the winding drops about 0.338 mV and dissipates 1.15 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 131 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The second saturation column, 6.2 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC8 line-up this part is number 14 of 16 by inductance, between 0.175 uH and 47.3 uH.

    One step down the table, HC8-150-R, sits at 15.02 uH with 4.1 A and 68.6 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 99.5 mOhm becomes roughly 152 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Confirm the part marking is visible after placement for traceability.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.

    Frequently Asked Questions

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.