Eaton HC8-4R5-R 4.52 uH Powder Iron Inductor, 8 A
Eaton HC8-4R5-R 4.52 uH Powder Iron Inductor, 8 A

Eaton HC8-4R5-R 4.52 uH Powder Iron Inductor, 8 A

Share
Eaton HC8-4R5-R: powder iron high-current inductor, 4.52 uH ±20%, 8 A Irms, Isat 7.7 A, DCR 18.6 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-4R5-R 4.52 uH Powder Iron Inductor, 8 A

    HC8-4R5-R at a glance: powder iron high-current inductor, 4.52 uH ±20%, 8 A Irms, Isat 7.7 A (15% rolloff), DCR 18.6 mOhm, 10.9 x 10.4 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHC8-4R5-R
    OCL (open circuit inductance)4.52 uH ±20%
    Irms (DC, 40 °C rise)8 A
    Isat (15% rolloff)7.7 A
    Isat2 (30% rolloff)13.5 A
    DCR typical @ +20 °C18.6 mOhm
    Volt-time rating (V-us)8.5
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Outline Drawing

    HC8-4R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.

    With 18.6 mOhm typical, the I-squared-R loss at the full 8 A rating is about 1.19 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 134 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The second saturation column, 13.5 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    Of the 16 values listed for HC8, this is the 8th, in a family covering 0.175 uH to 47.3 uH.

    The next value up in the same family, HC8-5R6-R, gives 5.65 uH at 6.7 A and DCR 26.3 mOhm: the extra inductance costs about 1.8 A of rated current.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 18.6 mOhm becomes roughly 28.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Check the volt-time rating against the applied V-us at the switching frequency.
    • Check that the inductance at the working DC bias still meets the ripple target.
    • Decide which rolloff column the loop can tolerate, then stay with that column.

    Frequently Asked Questions

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Why is the DCR higher than a ferrite part of the same size?
    Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products