| Parameter | Value |
|---|---|
| Orderable part number | HC8-4R5-R |
| OCL (open circuit inductance) | 4.52 uH ±20% |
| Irms (DC, 40 °C rise) | 8 A |
| Isat (15% rolloff) | 7.7 A |
| Isat2 (30% rolloff) | 13.5 A |
| DCR typical @ +20 °C | 18.6 mOhm |
| Volt-time rating (V-us) | 8.5 |
| Package | 10.9 x 10.4 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4120 |

Drawing reproduced from Eaton Technical Data 4120: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.
With 18.6 mOhm typical, the I-squared-R loss at the full 8 A rating is about 1.19 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 134 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The second saturation column, 13.5 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Of the 16 values listed for HC8, this is the 8th, in a family covering 0.175 uH to 47.3 uH.
The next value up in the same family, HC8-5R6-R, gives 5.65 uH at 6.7 A and DCR 26.3 mOhm: the extra inductance costs about 1.8 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 18.6 mOhm becomes roughly 28.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.
Which saturation column should I design to?
The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.