Eaton HC8-6R9-R Powder Iron Inductor 6.90 uH, Isat 6.2 A
Eaton HC8-6R9-R Powder Iron Inductor 6.90 uH, Isat 6.2 A

Eaton HC8-6R9-R Powder Iron Inductor 6.90 uH, Isat 6.2 A

Share
Eaton HC8-6R9-R: powder iron high-current inductor, 6.90 uH ±20%, 6.4 A Irms, Isat 6.2 A, DCR 28.9 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8-6R9-R Powder Iron Inductor 6.90 uH, Isat 6.2 A

    HC8-6R9-R at a glance: powder iron high-current inductor, 6.90 uH ±20%, 6.4 A Irms, Isat 6.2 A (15% rolloff), DCR 28.9 mOhm, 10.9 x 10.4 mm.

    Specification Table

    ParameterValue
    Orderable part numberHC8-6R9-R
    OCL (open circuit inductance)6.90 uH ±20%
    Irms (DC, 40 °C rise)6.4 A
    Isat (15% rolloff)6.2 A
    Isat2 (30% rolloff)10.9 A
    DCR typical @ +20 °C28.9 mOhm
    Volt-time rating (V-us)10.5
    Package10.9 x 10.4 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4120

    Mechanical Dimensions & Pad Layout

    HC8-6R9-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4120: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    Powder iron is the material choice that gives this family its soft saturation curve and its stable inductance over temperature. There is no thermal aging of the binder, so the inductance you measure on day one is the inductance you have after a thousand thermal cycles.

    At the rated 6.4 A the winding dissipates about 1.18 W in copper alone, using the typical DCR of 28.9 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 15% rolloff, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 133 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    The second saturation column, 10.9 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    The HC8 family spans 0.175 uH to 47.3 uH; this row sits at position 10 of 16.

    The next value up in the same family, HC8-8R2-R, gives 8.27 uH at 5.5 A and DCR 39.6 mOhm: the extra inductance costs about 1.2 A of rated current.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 4.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 28.9 mOhm becomes roughly 44.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Compare the two saturation columns before fixing the current limit in the controller.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.

    Frequently Asked Questions

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products