| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-100-R |
| OCL (open circuit inductance) | 9.90 uH ±20% |
| Irms (DC, 40 °C rise) | 4.3 A |
| Isat (15% rolloff) | 6.8 A |
| Isat2 (30% rolloff) | 3.8 A |
| DCR typical @ +20 °C | 62.9 mOhm |
| Volt-time rating (V-us) | 9.3 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The core is iron powder held in a high-temperature non-organic binder. That construction does not saturate abruptly: as current rises the permeability falls progressively, so the inductance droops instead of collapsing. For a switching regulator working near its current limit during a transient, that behaviour keeps the control loop in a known place.
At the rated 4.3 A the winding dissipates about 1.16 W in copper alone, using the typical DCR of 62.9 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Stored energy at Isat is about 229 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The second saturation column, 3.8 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Within the HC8LP family this is value 12 of 16, in a range that runs from 0.17 uH to 47.9 uH.
One step down the table, HC8LP-8R2-R, sits at 8.37 uH with 4.5 A and 58 mOhm – the lower inductance buys about 1.1 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 62.9 mOhm becomes roughly 96.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.
How do I estimate the inductance at my operating current?
Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.
Does the inductance drift with age?
The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.