| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-1R9-R |
| OCL (open circuit inductance) | 1.92 uH ±20% |
| Irms (DC, 40 °C rise) | 10.1 A |
| Isat (15% rolloff) | 8.7 A |
| Isat2 (30% rolloff) | 15.5 A |
| DCR typical @ +20 °C | 11.5 mOhm |
| Volt-time rating (V-us) | 4.1 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.
The DCR figure of 11.5 mOhm is what sets the efficiency: at 10.1 A the winding drops about 0.116 mV and dissipates 1.17 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Saturation is quoted as 15% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 72.7 uJ, the number that connects the inductance and the current rating into a single transient figure.
The second saturation column, 15.5 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
The HC8LP family spans 0.17 uH to 47.9 uH; this row sits at position 5 of 16.
One step down the table, HC8LP-1R2-R, sits at 1.35 uH with 12.4 A and 7.5 mOhm – the lower inductance buys about 4.1 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 11.5 mOhm becomes roughly 17.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
Does the inductance drift with age?
The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.
Why is the DCR higher than a ferrite part of the same size?
Iron powder has lower permeability, so more turns are needed for the same inductance, and more turns mean more copper. The compensation is the much higher saturation flux density.