| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-220-R |
| OCL (open circuit inductance) | 21.7 uH ±20% |
| Irms (DC, 40 °C rise) | 2.8 A |
| Isat (15% rolloff) | 2.6 A |
| Isat2 (30% rolloff) | 4.6 A |
| DCR typical @ +20 °C | 149 mOhm |
| Volt-time rating (V-us) | 13.7 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.
Copper loss at the rated current works out to roughly 1.17 W from a typical DCR of 149 mOhm at 2.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 15% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Stored energy at Isat is about 73.3 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The second saturation column, 4.6 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
The HC8LP family spans 0.17 uH to 47.9 uH; this row sits at position 14 of 16.
One step down the table, HC8LP-150-R, sits at 15.2 uH with 3.4 A and 99.4 mOhm – the lower inductance buys about 1.1 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 149 mOhm becomes roughly 228 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
What is soft saturation?
The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.
How do I estimate the inductance at my operating current?
Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.
How do I estimate the inductance at my operating current?
Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.